FLEXIBLE AUTHENTICATION
Choose the secure access method that works best for your teams, including the electronic OneKEY and the OneKEY App.
SECURE EVERY ENTRY POINT
Works across a wide range of manual and automatic doors, so you can standardize access without adding another system.
REMOTE VISIBILITY & MANAGEMENT
Issue credentials, deploy updates, monitor device health, and review access activity—all from one centralized platform.

Beyond Merchandise. Now Securing Controlled-Access Spaces.
Extend access beyond merchandise to stockrooms, employee entrances, receiving areas, and more. Bring every access point into the OneKEY Ecosystem for greater control over who has access, when, and where.
-
Enterprise-Grade Security: Protect every entry point with multiple layers of security that safeguard credentials, prevent unauthorized access, and detect tampering.
-
Multiple Authentication Methods: Choose from multiple access methods, including OneKEY electronic keys, NFC tap, BLE, and mobile app credentials.
-
Temporary & Visitor Credentials: With OnePASS, provide secure, time-limited access for visitors and third parties without adding permanent users to your system.
-
Certified for Secure Access: Designed to meet key U.S. safety, security, and access control standards, so you can deploy with confidence across different applications.
-
Ready for Every Environment: Designed for indoors and outdoor use, the Door Reader is IP66-rated, and operates reliably in dust, rain, and temperatures from -20°C to 66°C.
-
Fast, Local Configuration: Adjust how long doors stay unlocked or open without software or remote support, and use physical dials to control when alerts are triggered.
-
Instant System Status: Quickly identify reader status, connectivity, door status, and firmware updates through intuitive LED and software indicators.
-
Easy Part Replacement: Individual controllers, readers, and reader plates are available separately for simpler, more cost-effective maintenance.
InVue LIVE Door Access is a network-connected access control system that enables businesses to manage and secure entry points using the OneKEY Ecosystem. The system includes a Single-Door Access Controller and up to two Door Readers. The controller manages authorized access, monitors door and alarm inputs, and operates electronic locking hardware, while the readers authenticate users through OneKEY credentials.
Users can unlock doors using a physical OneKEY electronic key or the OneKEY mobile app. When a user requests access, the LIVE Door Reader communicates with the controller, which verifies authorization settings and activates the door relay to unlock the door.
Each LIVE Door Access controller supports up to two readers, allowing businesses to configure access control for both entry and exit through a single door. This flexibility makes the system suitable for locations requiring controlled access from either side of a doorway.
InVue LIVE Door Access supports multiple types of manual and automatic doors, including:
- Pedestrian swing doors
- Overhead and garage doors
- Automatic sliding doors
This flexibility allows businesses to manage access across different entry points, such as employee entrances, stockrooms, and receiving areas, within the OneKEY Ecosystem. Compatibility depends on the door’s locking hardware and control configuration.
The InVue LL501 LIVE Door Access Controller uses Power over Ethernet (PoE+) and supports IEEE 802.3af/at/bt standards. This allows the controller to receive power through its Ethernet connection. External electronic locks, automatic doors, and other connected control systems require separate power sources.
Yes. The LIVE Door Reader has an IP66 rating, providing protection against dust and powerful water jets, making it suitable for outdoor installations. The LIVE Door Access Controller is designed for indoor installation only.
Yes. The LIVE Door Access Controller supports Bluetooth Low Energy (BLE) wireless communication for system status reporting and communications. The controller also uses a wired Ethernet connection for network connectivity and Power over Ethernet (PoE+) power.
InVue LIVE Door Access supports both fail-safe and fail-secure electronic locking hardware:
- Fail-safe locks: Unlock when power is removed.
- Fail-secure locks: Remain locked when power is removed.
This compatibility allows businesses to select electronic locking hardware based on their security requirements and door configuration.
Yes. When connected to a Door Position Input (DPI) sensor, LIVE Door Access can detect doors opened without authorization or left open beyond a configured time limit. These events can trigger forced-open or held-open alarms and door status notifications, helping businesses identify potential security issues.
The LIVE Door Access Controller supports three configurable monitoring inputs:
- Request to Exit (REX): Monitors exit requests.
- Door Position Input (DPI): Monitors whether a door is open or closed.
- Alarm Input: Monitors an external alarm signal.
Each input can be configured as normally open or normally closed and supports multiple wiring supervision options.
InVue LIVE Door Access provides system and door status information through Bluetooth Low Energy (BLE) communication, including:
- Door forced-open alarms
- Door held-open alarms
- Controller tamper status
- Alarm input status
- Reader connection status
- Door position status
- Door secure status
- Wiring supervision errors
These status indicators help businesses monitor access control hardware and identify potential security or connectivity issues.
Yes. The LIVE Door Access Controller includes a built-in tamper-detection switch that identifies when the controller cover is removed. This provides an additional layer of physical security by helping identify potential interference with access control equipment.
The LIVE Door Reader uses LED indicators to communicate door and system status:
- Red: Door locked
- Green: Door unlocked
- Flashing red: Alarm or attention condition
- Blue blink: Firmware update in progress
- Off: Reader inactive
These visual indicators help users and installers quickly recognize access and system conditions.
The LIVE Door Reader supports several mounting options, including direct wall mounting, single-gang electrical boxes, and double-gang electrical boxes.
The LIVE Door Access Controller can be mounted directly to a wall or an electrical gang box, providing installation flexibility for different building layouts and access control configurations.
InVue LIVE Door Access components support different operating temperature ranges:
- LIVE Door Access Controller: 32°F to 120.2°F (0°C to 49°C)
- LIVE Door Reader: -4°F to 150.8°F (-20°C to 66°C)
The system is tested for operation at 85% relative humidity and 86°F (30°C). The IP66-rated reader is suitable for outdoor environments, while the controller is intended for indoor use.
Not sure where to start? We’re here to help. Our team of experts can make personalized recommendations for your business.
Please complete the form below and someone from our team will be in contact shortly.